   On-board energy storage in DC systems  evaluated  
Modern energy storage devices permit the storage of braking energy on-board for use in subsequent acceleration phases. Especially in DC system, where energy losses in the distribution network are high, this could be an interesting alternative to feeding back energy into the supply system. Furthermore reduced peak load is beneficial for system capacity, voltage stability and energy costs.
Technology field: Regenerative braking and energy management
close main section General information
  close sub-section Description
   

Principle

Modern energy storage devices permit the storage of braking energy on-board for use in subsequent acceleration phase. Especially in DC systems, where energy losses in the distribution network are high, this could be an interesting alternative to feeding back energy into the supply system.

Without on-board energy storage much of the potential for brake energy recovery is not exploited because the system is often not able to take up the power. By means of energy storage, brake energy recovery becomes independent of load situation in the supply system. This way the recovery rates and energy savings may be raised substantially.

Furthermore the peak loads of the supply system are reduced, with results beneficial both for system capacity, voltage stability and energy costs.

Energy storage in the driving cycle

Figure 1 shows the use of energy storage in a typical driving cycle consisting of the phases acceleration – constant speed – braking – standstill.

 

Figure 1: Driving Cycle and Storage Cycle. Line 1: Speed v, tractive effort T. Line 2: Power P, Energy E. Line 3: Voltage U, current i of a supercapacitor for energy storage

Driving cycle.jpg

Source: Hentschel et al. 2000

During braking phases the kinetic energy of the vehicle is transformed into another energy type (e.g. electrostatic energy in the case of a capacitor) and stored in the storage device. When the vehicle stands still the energy storage device should be fully charged to be able to deliver energy during the subsequent acceleration phase. The energy supply during acceleration is supported by the stored energy. The energy management system should be designed in such a way that the external energy supply never needs to deliver the full accelerating power (an important condition to downsize energy supply! cf. below). When driving at maximum speed the storage device should be completely discharged.

Integration into drive system

Figure 2: Integration into drive system

Storage_system.gif

Source: IZT

Choice of energy storage device

The choice of the best energy storage device heavily depends on the individual vehicle and service type. The following table shows the main characteristics to be looked at in an individual application context and the corresponding storage parameters.

Characteristics of application context Corresponding parameter of storage device
Braking time Charging time / power density
Braking energy Energy density
Drive cycles in lifetime Product life / reliability
 Source: IZT

Table 1 gives the relevant characteristics for some trains.

Table 1: Relevant characteristics of some trains Regional Multiple Unit (EMU) Suburban EMU

Regional Multiple Unit (EMU)

Suburban EMU      (DC, 4 cars)

Light rail vehicle

Mass of train (brutto)

250 t

160 t

39 t

Top speed

160 km/h

100 km/h

70 km/h

Drive power

4000 kW

1200 kW

300 kW

Maximum traction effort

250 kN

180 kN

60 kN

Braking power

4800 kW

3000 kW

900 kW

Maximum braking effort

270 kN

200 kN

100 kN

Stored kinetic energy

70 kWh

16 kWh

2 kWh

Braking time

50 s

15 s

9 s

Drive cycles per year

40.000

100.000

300.000

Drive cycles in lifetime (106)

0,8

2

6

Source: Hentschel et al. 2000

The Ragone diagram plotting energy density against power density is a convenient means to compare different storage technologies and assess their suitability for different vehicles. Figure 3 shows the position of relevant storage technologies in the Ragone diagram and the charging times. They are labelled by train types with corresponding braking times.

Figure 3: Ragone diagram and charging times (corresponding to braking times of different trains)

Ragone_diagram_trains.gif

Source: IZT, data mainly from: Hentschel, Müller et al. 2000.

Batteries have very high energy densities but low power densities leading to very high charging times. Nickel metal hydride batteries have sufficient power densities but do not meet the lifespan requirements. Batteries are therefore presently not the first choice for on-board storage.

Flywheels have both high power and high energy densities and are therefore ideally fitted to most situations, especially regional trains.

Supercaps which have made considerable development progress in recent years are beginning to become attractive for railway applications especially light rail urban vehicles, but there are also high-energy supercaps that could be interesting for storage solutions on heavy vehicles.

Superconducting magnetic energy storage (SMES) is of the extreme low-energy high-power type and is therefore not an attractive option for brake energy storage.

open main section General criteria
open main section Environmental criteria
open main section Economic criteria
no data available Application outside railway sector (this technology is railway specific)
open main section Overall rating
References / Links:  Hentschel et al. 2000
Attachments:
Related projects:  Studies performed on energy storage systems;  THALES: hybrid tram train with on-board ultracapacitors
Contact persons:
 date created: 2002-10-09
 
 
© UIC - International Union of Railways 2003
 
Aktionmenu
 
 Your contribution
   add technology
 Views of this page
   show overview
   show evaluation
   show details
 Print options
   print data sheet
   print screen
 Help
   Evaluation briefing
   Technology list
    French - German