back to list go back to technology list      previous previous technology  next technology  next

   Stationary energy storage  evaluated  
Stationary energy storage devices can substantially enhance the recovery of braking energy in DC systems. The energy stored along the track or at substations can be used for traction purposes either by the same or by other trains. Apart from energy savings, stationary storage equalizes the variation of power demand and has thus a stabilising effect on catenary voltage.
Technology field: Regenerative braking and energy management
close main section General information
  open sub-section Description
close main section General criteria
  open sub-section Status of development: test series
  Time horizon for broad application: 2 - 5 years
  Expected technological development: dynamic
  Benefits (other than environmental): big
  Barriers: high
  Applicability for railway segments: medium
    Type of traction:  electric - DC
    Type of transportation:  passenger - regional lines, passenger - suburban lines
    Grade of diffusion into railway markets:
  Diffusion into relevant segment of fleet: not applicable
  Share of newly purchased stock: (no data)
  Market potential (railways): low
close main section Environmental criteria
  close sub-section Impacts on energy efficiency:
  Energy efficiency potential for single vehicle: 5 - 10%
  Energy efficiency potential throughout fleet: 1 - 2%
   

Status quo in DC local networks:

~ 40% of energy demand goes into kinetic (or potential) energy and could theoretically be recovered.

If vehicles are equipped with regenerative brakes, 10-30% are recovered and used by other trains (in dense networks). The rest is converted into heat in on-board resistors.

The installation of stationary energy storage systems is an interesting option on peripheric routes with low train density and/or high velocities and slopes. In such areas of the network, a direct use by other trains is rare, so recovery rate will usually be < 10% (of total energy demand), leaving > 30% of theoretical potential for energy savings through stationary energy storage. There are however further limitations:

Losses in energy transmission, conversion and storage

Layout of storage system is not sufficient to store the entire braking energy (e.g. in the Cologne case, the average braking current is ~1000A, the flywheel can only take 450A). The layout is usually a trade-off between technological and economic considerations

In the Cologne case, the average power demand of the substation equipped with a flywheel was only 160 kW compared to 210 kW without energy storage. This means energy savings of about 24%. On has to keep in mind that these savings were realised at a carefully chosen location and can by no means be generalised to an entire network.

The system-wide effect achievable by putting storage systems at all “hot spots” of the network is very difficult to assess and strongly dependant on the specific network layout. Given the above figures and the limitations mentioned, it seems reasonable to assume that the overall effect for a local DC network could be between 2-10% depending on the density of "hot spots".

  Other environmental impacts: neutral
    (no details available)
open main section Economic criteria
no data available Application outside railway sector (this technology is railway specific)
close main section Overall rating
  close sub-section Overall potential: promising
  Time horizon: mid-term
    The installation of stationary energy storage capacity is one of several measures to increase the effectiveness of braking energy recovery in DC networks. Existing experience shows both technological feasibility and high energy saving potential. However, investment costs are high. Therefore the measure may be limited to hot spots of the network. Too little is known about the compared profitability between stationary storage and the two alternative technologies: on-board storage and inverter equipment for substations. More research is needed in this area.
References / Links:  Godbersen, Gunselmann 2001;  Gunselmann et al. 2000
Attachments:
Related projects:  Studies performed on energy storage systems
Contact persons:
 date created: 2002-10-09
 
 
© UIC - International Union of Railways 2003
 
Aktionmenu
 
 Your contribution
   add technology
 Views of this page
   show overview
   show evaluation
   show details
 Print options
   print data sheet
   print screen
 Help
   Evaluation briefing
   Technology list
    French - German